Multi-Motion Compensation for Computed Tomography
Case ID:
C15119
Report of Invention:
1/3/2018
Web Published:
5/24/2019
Unmet Need
During computed tomography (CT) or cone-beam CT, scans can be affected due to patient motion that causes significant artifacts that diminish image quality. This is functionally the case because of slow image acquisition speed, causing artifacts in the image due to patient’s difficulty in following commands and remaining still. Furthermore, motion patterns occurring in brain imaging are even more challenging due to more rapid, aperiodic, and of larger amplitude. Currently, there is an “auto-focus” motion compensation method where the patient motion is iteratively estimated so the image is reconstructed to its maximum capability. However, there is a problem when encountering a critical care imaging offers even larger amplitude and rapid displacement, which challenges this autofocus optimization method. In addition, there is a need to optimize and improve reconstruction methods so that they are able to consider multiple fields of views. This allows for movement to not be as destructive to image quality.
Technology Overview
The inventors have proposed a new autofocus method, called “Multi-Motion,” that accounts for multiple regions and objects undergoing different motion patterns. This means it can take into account a patient’s head rolling within a head cradle or even a lower part of the leg moving separate speeds than the upper portion of the leg. This methodology uses novel-preconditioning to begin motion estimates, improving the efficiency of the Multi-Motion algorithm. This novel innovation doesn’t require the motion-free 3D image as an input for 3D-2D registration as the current method does. By using an uncompensated 3D image reconstruction that actually generates 2 or more sub-regions, this method can model complex deformable motion. This algorithm doesn’t require any trackers, fiducials, or prior scans for estimation. The novel two-pronged methodology of including a preconditioning stage and modifying reconstruction methods to accommodate multiple fields of motion not only improves on the accuracy but also the efficiency of prior art.
Stage of Development
The inventors have proposed a novel Multi-Motion algorithm to significantly reduce the effects of patient motion on CT scans. They have evaluated their algorithm through experimentation, and they plan to move from ongoing application to collecting clinical data of a prototype CBCT scanner.
Patent Information:
Title
App Type
Country
Serial No.
Patent No.
File Date
Issued Date
Expire Date
Patent Status
MULTI-MOTION COMPENSATION FOR HIGH-QUALITY CONE-BEAM CT OF THE HEAD
PCT: Patent Cooperation Treaty
United States
17/056,639
12,039,738
11/18/2020
7/16/2024
4/29/2041
Granted
Direct Link:
https://jhu.technologypublisher.com/technology/34401
Inventors:
Category(s):
Technology Classifications > Medical Devices > Imaging,
Get custom alerts for techs in these categories/from these inventors:
Subscribe for JHTV Updates
For Information, Contact:
Lisa Schwier
lschwie2@jhu.edu
410-614-0300
Save This Technology:
Bookmark this page
Download as PDF
JHTV Home
|
Search
|
Login/Subscribe
2017 - 2022 © Johns Hopkins Technology Ventures. All Rights Reserved. Powered by
Inteum